You receive a "Microsoft Project cannot access the Microsoft Project Server" error message when you log on to Microsoft Project Professional or Microsoft Project Web Access
This article was previously published under Q323025
SYMPTOMS
When you try to log on to Microsoft Project Professional or Microsoft Project Web Access, you may receive the following error messages:
Microsoft Project Server Security Login
Please enter your login information for the server
Http://ServerName/ProjectServer
Microsoft Project cannot access the Microsoft Project Server
Http://ServerName/ProjectServer
Please check the Server URL in the Collaborate tab of the Options dialog box
(Tools menu). Make sure the server is functioning correctly and is a valid
Microsoft Project 2002 Server. Note that you cannot display pages from a
Microsoft Project 2000 Server inside Microsoft Project 2002.
Alternatively, if you click
Work Offline on the
File menu, create a Project Server Account, and then click
Test
Connection, you may receive the following error message:
Microsoft Project Server has returned an unexpected response.
If you then click
View to view the server response in your browser, or if you try to connect to Microsoft Project Web Access, you may receive the following error message:
The Server at Http://ServerName/ProjectServer returned the following error to
Microsoft Project
Http 401.2 Unauthorized: Login failed due to server configuration
Internet Information Services
CAUSE
Possible Cause 1 This issue may occur if you are using a configuration script in Microsoft Internet Explorer for authentication on the computer that is running Microsoft Project Server.
Possible Cause 2 You have incorrect Internet Explorer security settings.
RESOLUTION
Resolution for Cause 1
To resolve this issue, follow these steps:
- Start Internet Explorer, and then click Internet Options on the Tools menu.
- Click the Connections tab, and then click LAN Settings.
- Click to clear the Use automatic configuration script check box.
- Click to select the Use a proxy server for your LAN check box, and then type the address and port number for your proxy server in the Address box and the Port Number box.
- Click to select the Bypass proxy server for local addresses check box, and then click OK.
Resolution for Cause 2: To resolve this issue, follow these steps:
- Start Internet Explorer, and then click Internet Options on the Tools menu.
- Click the Security tab, and then click Trusted sites.
- Click Custom Level
- Click the Automatic logon with current username and password button.
- Click OK.
APPLIES TO
- Microsoft Office Project Web Access
- Microsoft Office Project Professional 2003
- Microsoft Project 2002 Professional Edition
Community Feedback System
Very often, it takes hours to solve a problem. Very often, you've looked high
and low, and have tried a lot of solutions. When you finally found it, chances
are, it was because someone else helped you. Here's your chance to give back.
Use our community feedback tool to let others know what worked for you and what
didn't.
Please also understand that the community feedback system is not warranted to be
correct, it's simply a system that we've built to let people try and help each
other. If something in a feedback response doesn't make sense to you, or you're
not comfortable making changes that the feedback talks about (like registry
edits), please consult a professional.
Thank you for using kbAlertz.com Feedback System.
-- Scott Cate
|
Steve Walker
- Steve.Walker NOSPAM-AT-NOSPAM NOSPAMdtag.com
|
Report As Irrelevant
|
| Written:
9/20/2004 2:24 PM |
|
|
(Optional) Name
(Optional)
Public URL Or Email
Comments
No
HTML -- Text Only Please